MODEL PROFILE
Signal or code
Error codes and display signals
The official manual linked for this model documents these messages. Some indicators apply only to variants that display them; each entry is labeled as a code, indicator, or status.
No matching signal for this model.
Model and error-code facts may be shown in the language of the original source.
Official PDF manual
Jump to manual pages
Open the official PDF at pages that document signals for this model.
MODEL OVERVIEW
About this model: GE GZS24NMYES
GE GZS24NMYES is a 23.6-cu-ft counter-depth side-by-side with a documented XWFE filter display that separates service reminders, filter recognition and leak detection.
Identify the counter-depth model and its internal panel
GZS24NMYES is GE's 23.6-cu-ft counter-depth side-by-side, with 15.7 cubic feet assigned to fresh food and 7.9 to the freezer. Its extra-tall eleven-inch dispenser serves water and ice, while the factory-installed icemaker sits in the door and leaves more shelf space in the freezer. Unlike a display in the door face, the exact product places its internal digital controls on the right wall of the fresh-food section. The GE owner PDF linked by this exact SKU names the GZS family on its cover, and the rendered control drawing on page ten includes Replace Filter, Filter Expired, Leak Detected, Door Alarm and Control Lock. Those are the messages and buttons independently listed in the exact product specification. Factory temperature presets are 37°F in the refrigerator and 0°F in the freezer; GE asks for 24 hours after a change before judging the result. The filter messages should therefore be read on this model's internal panel, not confused with the dispenser's light or a temperature setting.
Separate filter-life messages from filter recognition
Replace Filter is an early service reminder: the manual says it illuminates when about ten percent of the filter's life remains. Filter Expired is later; the guide bases expiry on water-use capacity or six months, whichever comes first. The cartridge is an XWFE fitted low in the fresh-food compartment behind a rectangular access door. A reduced flow to the water or ice outlet can justify replacement before an expiry message. A third state, Not filtering, has a different meaning in the troubleshooting table: a bypass plug is installed, so water is being dispensed without cartridge filtration. Err is different again. The display shows it when no suitable filter is present or the wrong filter is installed; the troubleshooting chart also discusses failed communication with the cartridge and says to check that it is XWFE rather than XWF, inspect its label and confirm seating. Treating all four as a generic 'change filter' code would hide whether the appliance actually detects a cartridge. Record the literal message and what is physically installed before clearing or replacing anything.
Respond to leaks and replace the XWFE cartridge correctly
Leak Detected deserves its own check. The manual says it lights when water is found outside the filter, and the page-34 chart pairs this state with disabled water and ice. It directs replacement of a leaking filter and wiping the surrounding area; it separately mentions household-line connections when water appears on the floor. For a normal cartridge change, GE shows how to open the lower access panel, pull and quarter-turn the old XWFE cartridge out, align the new filter's two ports and turn it clockwise only until it stops. Overtightening is specifically prohibited. Close the housing and run roughly two gallons, or about five minutes, through the dispenser; brief spurting or bubbles can occur during flushing. If no replacement is available, use the proper bypass plug, since the dispenser and icemaker need either a filter or that plug. A bypass explains Not filtering, but it is not a remedy for water visibly escaping around the filter. After a leak message, document where the water appeared and whether the water/ice outlets were disabled.
Check door, temperature and dispenser states independently
Not every illuminated or audible condition belongs to the filter circuit. The exact GZS24NMYES has Door Alarm and Control Lock; the manual says an open refrigerator or freezer door can sound an alert, while holding Control Lock for three seconds disables the dispenser, feature buttons and temperature controls. A silent dispenser with Locked showing first calls for checking that deliberate control state. A beeping unit first calls for closing the door and looking for packages that block its seal, rather than swapping the XWFE. The owner's troubleshooting pages also distinguish 24-hour cooling stabilization after first connection or heavy loading from a filter message. A floor puddle can involve the house water connection, whereas Leak Detected refers to the filter area. Note which compartment is warm, the displayed temperature, whether the door alarm or lock is active, and the exact filter wording when asking for help. GE offers WiFi only as an optional accessory on this SKU, so connected alerts should not be assumed available. The family manual also includes optional modes; follow the physical controls and this model's exact specification when deciding what is installed.
Verified model details
Replace Filter and Filter Expired mark different points in the cartridge life.
Source for this detail · Source page: 10Leak Detected and Err have different causes and affect water or ice output.
Source for this detail · Source page: 16The exact model has a lower fresh-food XWFE filter and an in-door icemaker.
Source for this detail · Source page: 34
This description summarizes the linked source documents; check each cited source for your exact model and region.
Manufacturer source
Open official source
GE® 23.6 Cu. Ft. Counter-Depth Side-By-Side Refrigerator with Extra Tall Dispenser and In-Door Icemaker - GZS24NMYES
Open official sourceIf there is a safety risk, stop using the appliance and follow the manufacturer’s instructions.